The ID2 is the most flexible and advanced two-wire system on the market. Installers benefit from a choice of radial or loop wire modes. In the case of the radial configuration, no end of lines are required, and devices can be spurred off one another. Following the auto-configuration, each device on the system can be given a 20-character description. This means in the event of a fire or fault, the exact device will be displayed on the panel’s LCD display (for instance, “Main Office” or “Bedroom 1”).
The infinity ID2 system is priced very competitively, and by starting with one of these kits, you will save even more. By purchasing this kit, you will benefit from 1 free detector, two free batteries, one free Mains Safety Isolator, and a free check-it tester spray over purchasing the panel, six detectors and 2 Manual Call Points separately.
This addressable fire alarm kit includes the following fire alarm equipment;=
Zones | 2 Zone, 4 Zone, 8 Zone |
---|
Only logged in customers who have purchased this product may leave a review.
Settings | Infinity ID2 2, 4, or 8 Zone Fire Alarm Kit remove | Menvier Surface Manual Callpoint C/W Backbox Optional Weatherproof (CX201, MBG914, FX201) remove | C-Tec Conventional Fire Alarm Panel remove | Infinity ID2 Detector With Optional Integral Sounder remove | KAC Conventional Indoor Manual Call Point remove | FireSmart 8 Zone Fire Alarm Conventional Kit remove | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Infinity ID2 2, 4, or 8 Zone Fire Alarm Kit remove | Menvier Surface Manual Callpoint C/W Backbox Optional Weatherproof (CX201, MBG914, FX201) remove | C-Tec Conventional Fire Alarm Panel remove | Infinity ID2 Detector With Optional Integral Sounder remove | KAC Conventional Indoor Manual Call Point remove | FireSmart 8 Zone Fire Alarm Conventional Kit remove | ||||||||||||||||
Image | ||||||||||||||||||||||
SKU | ||||||||||||||||||||||
Rating | ||||||||||||||||||||||
Price | £821.44 – £904.64 | £14.71 – £52.71 | £186.86 – £284.36 | £33.87 – £53.79 | £13.18 | £527.80 | ||||||||||||||||
Stock | In Stock
| In Stock
| In Stock
| In Stock
| In Stock
| In Stock
| ||||||||||||||||
Availability | In Stock | In Stock | In Stock | In Stock | In Stock | In Stock | ||||||||||||||||
Add to cart | ||||||||||||||||||||||
Description | The infinity ID2 system is priced very competitively, and by starting with one of these kits, you will save even more. |
| The Ctec conventional fire alarm panel is LPCB certified to the latest revisions of EN54 parts 2 and 4, offers an array of user and installer-friendly features at a very competitive price. | The Enhanced Infinity ID2 detector provides a comprehensive and customizable fire detection solution with its wide range of detection options... |
| The FireSmart 8 zone Conventional fire alarm kits contain all you need to get an installation underway in one complete package. | ||||||||||||||||
Content | Infinity ID2 2, 4 or 8 Zone Fire Alarm KitThe ID2 is the most flexible and advanced two-wire system on the market. Installers benefit from a choice of radial or loop wire modes. In the case of the radial configuration, no end of lines are required, and devices can be spurred off one another. Following the auto-configuration, each device on the system can be given a 20-character description. This means in the event of a fire or fault, the exact device will be displayed on the panel's LCD display (for instance, “Main Office” or “Bedroom 1”). The infinity ID2 system is priced very competitively, and by starting with one of these kits, you will save even more. By purchasing this kit, you will benefit from 1 free detector, two free batteries, one free Mains Safety Isolator, and a free check-it tester spray over purchasing the panel, six detectors and 2 Manual Call Points separately. | Cooper Menvier Callpoint optional WeatherproofThis attractively designed, simple-to-install range of call points has been specifically developed to be compatible with Menvier conventional fire panels. There are two versions of call points in this range. The MBG914 can be either surface or flush mounted, and the MBG917 is weatherproof. All call points are supplied as standard with a frangible glass element and a test key for ease of maintenance. A comprehensive range of accessories is available to maximise the functionality of the call point for particular applications. | The C-Tech conventional fire alarm panel is LPCB certified to the latest revisions of EN54 parts 2 and 4, and offers an array of user and installer-friendly features at a very competitive price.
Supplied in an attractive flush or surface mountable plastic enclosure, four and 8-zone versions are available, each featuring four conventional sounder circuits, class change and alert inputs, onboard fire and fault relays and combined keypad/key switch entry.
Various engineering functions are also provided, including selectable zone delays, coincidence and non-latching zone options. Comprehensive test and fault-finding facilities are also provided.
Features
| Introducing the Enhanced Infinity ID2 Detector with Optional Integral Sounder
The Enhanced Infinity ID2 detectors are designed to provide superior fire detection capabilities, offering various options to cater to fire detection needs. Available in multiple configurations, these detectors are equipped with advanced technology to ensure reliable and efficient fire detection. Moreover, they now have the added option of an integral sounder for enhanced alarm notification.
Optical Smoke Detection:The Infinity ID2 detector is equipped with an advanced optical smoke sensor that utilizes state-of-the-art technology to detect the presence of smoke particles. This highly sensitive sensor can promptly detect even the smallest smoke particles, ensuring early fire detection and minimizing the risk of false alarms.Rate or Rise Heat Detection:The Rate or Rise Heat detection option is ideal for areas prone to fast-developing fires. The Infinity ID2 detector utilizes a high-precision heat sensor that can quickly detect sudden temperature increases or a rise above a predefined threshold. This enables rapid fire detection, ensuring swift response and early fire suppression.Fixed Heat Detection:In environments where slow-developing fires are more likely, the Fixed Heat detection feature of the Infinity ID2 detector is invaluable. The fixed heat sensor is designed to detect a gradual increase in temperature over time, accurately identifying fire hazards and initiating the necessary actions to mitigate the risk.Combined Optical & Heat Detection:The Infinity ID2 detector offers a combined Optical & Heat detection option to provide comprehensive fire detection capabilities. This dual-sensor configuration combines optical smoke and heat detection advantages, ensuring optimal performance in diverse fire scenarios. The synergy between the two sensors increases the reliability and accuracy of fire detection, enabling early and precise fire alarm activation.Optional Integral Sounder:The Enhanced Infinity ID2 detector now offers an optional integral sounder, greatly enhancing alarm notification capabilities. When the detector detects a fire, the integral sounder is triggered, emitting a loud and attention-grabbing sound to alert occupants. This additional audio alert ensures that people are promptly notified of the fire hazard, facilitating quick evacuation and minimizing potential risks. The Enhanced Infinity ID2 detector provides a comprehensive and customizable fire detection solution with its wide range of detection options and the optional integral sounder. These detectors are designed to ensure the highest safety and peace of mind in various environments, including residential, commercial, and industrial settings. Stay protected with the Enhanced Infinity ID2 detector, offering advanced fire detection and alarm features for maximum safety. | KAC Conventional Indoor Manual Call PointInstallation efficiency, flexibility and full compliance with the latest standards are at the heart of the new MCP indoor call point range. Installation time and, ultimately, cost is of paramount importance to any fire or security installer. The MCP range directly reflects this need by providing a unique ‘plug and play’ concept to reduce installation time. All new MCP products utilise a special terminal block, where all initial installation cabling is terminated. This terminal block is then connected to the back of the MCP. Simple but effective, with no re-termination required and no time wasted. New standards and legislation allow break glass and resettable operating elements to be used within a manual call point. To provide you with the greatest ‘flex-ability’, the new MCP range can be configured as either a break glass or resettable unit by simply changing from one element to another. No other additional parts or alternative products need to be ordered. All MCP indoor call point products also help preserve the integrity of the overall system, as illegal removal of the product lid will result in the call point operating and the system going into alarm. Full compliance with the latest standards is essential, and the new MCP indoor call point range is fully approved to the latest EN54-11 standard (Compliant markings only). The MCP1A product version has a resistor and normally open, clean contact electrical options. These options are easily utilised by simply connecting the terminal block to the required connection in the back of the MCP1 product. Various resistor versions are available, with both 470W and 680W offered as standard. However, other resistor types can be provided upon request. The MCP1B product version allows for connection to ‘Savwire’ systems. | The FireSmart 8 zone Conventional fire alarm kits contain all you need to get an installation underway in one complete package.
Choose additional devices from the options box to speed up the ordering process.
| ||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||
Additional information |
|
|
|
|
|
Reviews
There are no reviews yet.