Infinity ID2 2, 4 or 8 Zone Fire Alarm Kit

The ID2 is the most flexible and advanced two-wire system on the market. Installers benefit from a choice of radial or loop wire modes. In the case of the radial configuration, no end of lines are required, and devices can be spurred off one another. Following the auto-configuration, each device on the system can be given a 20-character description. This means in the event of a fire or fault, the exact device will be displayed on the panel’s LCD display (for instance, “Main Office” or “Bedroom 1”).

The infinity ID2 system is priced very competitively, and by starting with one of these kits, you will save even more. By purchasing this kit, you will benefit from 1 free detector, two free batteries, one free Mains Safety Isolator, and a free check-it tester spray over purchasing the panel, six detectors and 2 Manual Call Points separately.

Kit Contents

This addressable fire alarm kit includes the following fire alarm equipment;=

  • 1 x Infinity ID2 2,4, or 8 Zone panel (depending upon chosen kit)
  • 2 x Yuasa 7.2Ah Sealed Lead Acid Battery (upgraded from previous 3.4ah)
  • 6 x ID2-OP/S Optical Smoke Detectors with Sounder
  • 1 x ID2-HR/S Rate of Rise Heat Detector with Sounder
  • 2 x ID2 Manual Call Point c/w Covers and Flush Bezels
  • 1 x Red Safety Isolator Switch

Additional information

Zones

2 Zone, 4 Zone, 8 Zone

Brand

Zeta

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Quick Comparison

SettingsInfinity ID2 2, 4, or 8 Zone Fire Alarm Kit removeMenvier Surface Manual Callpoint C/W Backbox Optional Weatherproof (CX201, MBG914, FX201) removeC-Tec Conventional Fire Alarm Panel removeInfinity ID2 Detector With Optional Integral Sounder removeKAC Conventional Indoor Manual Call Point removeFireSmart 8 Zone Fire Alarm Conventional Kit remove
NameInfinity ID2 2, 4, or 8 Zone Fire Alarm Kit removeMenvier Surface Manual Callpoint C/W Backbox Optional Weatherproof (CX201, MBG914, FX201) removeC-Tec Conventional Fire Alarm Panel removeInfinity ID2 Detector With Optional Integral Sounder removeKAC Conventional Indoor Manual Call Point removeFireSmart 8 Zone Fire Alarm Conventional Kit remove
Image
SKU
Rating
Price£821.44£904.64£14.71£52.71£186.86£284.36£33.87£53.79£13.18£527.80
Stock
In Stock
In Stock
In Stock
In Stock
In Stock
In Stock
AvailabilityIn StockIn StockIn StockIn StockIn StockIn Stock
Add to cart

Select options

Read more

Select options

Read more

Select options

Add to basket

DescriptionThe infinity ID2 system is priced very competitively, and by starting with one of these kits, you will save even more.
  • High visibility status LED
  • Standard and weatherproof versions are available
  • Wide range of accessories
  • Heavy duty terminals
  • Quick and simple to install
  • Fast-fit clip on the front cover
  • A single tool for test and access
The Ctec conventional fire alarm panel is LPCB certified to the latest revisions of EN54 parts 2 and 4, offers an array of user and installer-friendly features at a very competitive price.The Enhanced Infinity ID2 detector provides a comprehensive and customizable fire detection solution with its wide range of detection options...
  • Unique ‘Plug & Play installation concept
  • Total ‘Flex-Ability’ in the choice of the operating element
  • Anti-Tamper facility
  • Enhanced aesthetics
  • Fully approved to the latest standards
  • Backward compatibility
  • CPD Approved
The FireSmart 8 zone Conventional fire alarm kits contain all you need to get an installation underway in one complete package.
Content

Infinity ID2 2, 4 or 8 Zone Fire Alarm Kit

The ID2 is the most flexible and advanced two-wire system on the market. Installers benefit from a choice of radial or loop wire modes. In the case of the radial configuration, no end of lines are required, and devices can be spurred off one another. Following the auto-configuration, each device on the system can be given a 20-character description. This means in the event of a fire or fault, the exact device will be displayed on the panel's LCD display (for instance, “Main Office” or “Bedroom 1”). The infinity ID2 system is priced very competitively, and by starting with one of these kits, you will save even more. By purchasing this kit, you will benefit from 1 free detector, two free batteries, one free Mains Safety Isolator, and a free check-it tester spray over purchasing the panel, six detectors and 2 Manual Call Points separately.

Cooper Menvier Callpoint optional Weatherproof

This attractively designed, simple-to-install range of call points has been specifically developed to be compatible with Menvier conventional fire panels. There are two versions of call points in this range. The MBG914 can be either surface or flush mounted, and the MBG917 is weatherproof. All call points are supplied as standard with a frangible glass element and a test key for ease of maintenance. A comprehensive range of accessories is available to maximise the functionality of the call point for particular applications.
The C-Tech conventional fire alarm panel is LPCB certified to the latest revisions of EN54 parts 2 and 4, and offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure, four and 8-zone versions are available, each featuring four conventional sounder circuits, class change and alert inputs, onboard fire and fault relays and combined keypad/key switch entry. Various engineering functions are also provided, including selectable zone delays, coincidence and non-latching zone options. Comprehensive test and fault-finding facilities are also provided.

Features

  • C-Tech
  • LPCB Certified To The Latest Versions Of EN54 Parts 2 And 42
  • up to 8 Zone Circuits
  • 4 Conventional Sounder Circuits
  • Two On-Board Relays (Fire And Fault)
  • Integral 1.5A EN54-4/A2 Compliant Switch Mode PSU
  • 'Class Change' And Alert Inputs
  • Low Quiescent Current
  • Multiple Indicators
  • Space For 2 x 12V 3.2Ah SLA Batteries
Introducing the Enhanced Infinity ID2 Detector with Optional Integral Sounder The Enhanced Infinity ID2 detectors are designed to provide superior fire detection capabilities, offering various options to cater to fire detection needs. Available in multiple configurations, these detectors are equipped with advanced technology to ensure reliable and efficient fire detection. Moreover, they now have the added option of an integral sounder for enhanced alarm notification.

Optical Smoke Detection:

The Infinity ID2 detector is equipped with an advanced optical smoke sensor that utilizes state-of-the-art technology to detect the presence of smoke particles. This highly sensitive sensor can promptly detect even the smallest smoke particles, ensuring early fire detection and minimizing the risk of false alarms.

Rate or Rise Heat Detection:

The Rate or Rise Heat detection option is ideal for areas prone to fast-developing fires. The Infinity ID2 detector utilizes a high-precision heat sensor that can quickly detect sudden temperature increases or a rise above a predefined threshold. This enables rapid fire detection, ensuring swift response and early fire suppression.

Fixed Heat Detection:

In environments where slow-developing fires are more likely, the Fixed Heat detection feature of the Infinity ID2 detector is invaluable. The fixed heat sensor is designed to detect a gradual increase in temperature over time, accurately identifying fire hazards and initiating the necessary actions to mitigate the risk.

Combined Optical & Heat Detection:

The Infinity ID2 detector offers a combined Optical & Heat detection option to provide comprehensive fire detection capabilities. This dual-sensor configuration combines optical smoke and heat detection advantages, ensuring optimal performance in diverse fire scenarios. The synergy between the two sensors increases the reliability and accuracy of fire detection, enabling early and precise fire alarm activation.

Optional Integral Sounder:

The Enhanced Infinity ID2 detector now offers an optional integral sounder, greatly enhancing alarm notification capabilities. When the detector detects a fire, the integral sounder is triggered, emitting a loud and attention-grabbing sound to alert occupants. This additional audio alert ensures that people are promptly notified of the fire hazard, facilitating quick evacuation and minimizing potential risks. The Enhanced Infinity ID2 detector provides a comprehensive and customizable fire detection solution with its wide range of detection options and the optional integral sounder. These detectors are designed to ensure the highest safety and peace of mind in various environments, including residential, commercial, and industrial settings. Stay protected with the Enhanced Infinity ID2 detector, offering advanced fire detection and alarm features for maximum safety.

KAC Conventional Indoor Manual Call Point

Installation efficiency, flexibility and full compliance with the latest standards are at the heart of the new MCP indoor call point range. Installation time and, ultimately, cost is of paramount importance to any fire or security installer. The MCP range directly reflects this need by providing a unique ‘plug and play’ concept to reduce installation time. All new MCP products utilise a special terminal block, where all initial installation cabling is terminated. This terminal block is then connected to the back of the MCP. Simple but effective, with no re-termination required and no time wasted. New standards and legislation allow break glass and resettable operating elements to be used within a manual call point. To provide you with the greatest ‘flex-ability’, the new MCP range can be configured as either a break glass or resettable unit by simply changing from one element to another. No other additional parts or alternative products need to be ordered. All MCP indoor call point products also help preserve the integrity of the overall system, as illegal removal of the product lid will result in the call point operating and the system going into alarm. Full compliance with the latest standards is essential, and the new MCP indoor call point range is fully approved to the latest EN54-11 standard (Compliant markings only). The MCP1A product version has a resistor and normally open, clean contact electrical options. These options are easily utilised by simply connecting the terminal block to the required connection in the back of the MCP1 product. Various resistor versions are available, with both 470W and 680W offered as standard. However, other resistor types can be provided upon request. The MCP1B product version allows for connection to ‘Savwire’ systems.
The FireSmart 8 zone Conventional fire alarm kits contain all you need to get an installation underway in one complete package. Choose additional devices from the options box to speed up the ordering process.
  • 8 Zone FireSmart Conventional Panel: A premium system from a market-leading manufacturer, the control panel provides a highly cost effective conventional option for building premises.
  • FireSmart Optical Smoke Detector: A state-of-the-art optical chamber combined with an application-specific integrated circuit (ASIC) to quickly and accurately detect fires.
  • FireSmart Rate-of-Rise Heat Detector: The Heat Detector uses a state-of-the-art heat element combined with an application-specific integrated circuit (ASIC) to quickly and accurately detect fires.
  • FireSmart Diode Base: Diode base for use with the FireSmart range of detectors.
  • FireSmart Conventional Manual Call Point: An easy to operate fire alarm manual call point. Fully compliant with EN 54-11, each point is manufactured from impact-resistant ABS and includes a resettable press to break the glass.
  • FireSmart Sounder & Deep Base (Red): Provides outstanding sound output and low current draw. Specifically designed and approved to meet EN54-3 the Firesmart sounder delivers quality, reliability and extended operational life.
  • FireSmart 12vdc 3.4Ah Backup Batteries: 12v 3.2Ah batteries are specifically designed for use throughout the fire and security industries.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Zones

2 Zone, 4 Zone, 8 Zone

Version

Indoor, Outdoor

Zones

2 Zone, 4 Zone, 8 Zone

Integral Sounder

No, Yes

Detector Type

Fixed Heat 60 Deg, Fixed Heat 90 Deg, Opto-Heat, Rise of Heat, Smoke

Configuration

470 OHM & N/O, 680 OHM & N/O

Operating Element

Resettable, Glass

Mounting

Surface, Flush

Infinity ID2 2, 4, or 8 Zone Fire Alarm Kit £821.44£904.64
Shopping Cart

No products in the basket.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare